ELEVATOR CABLE

Elevator Cable

  • REACH
  • RoHS
Elevator Cable
elevator-cable

Applications

These power and control flat cables can be used on festooned systems on handling equipment as overhead cranes. They are designed for indoors and outdoors for ambient temperature down to -25°C.These cables can accept a trolley traveling speed up to 120m / min.

Standard

HD 359 S2, IEC 227 Part 6, EN 50214

Technical Data

Voltage Rating:

H05VVH6-F – 300/500V

H07VVH6-F – 450/750V

Colour Coding:

Core 1: Black.

Core 2: Light-blue.

Core 3: Green-yellow.

Core 4: Brown.

Core 5: Black.

Core 6 and above: All black numbered cores with one green / yellow earth core.

Cable Construction

Flexible bare copper, Class 5, IEC 60228

PVC (polyvinyl chloride) insulation

PVC (polyvinyl chloride) outer sheath

Cable Colour: Black

*A stripping thread can be used in each group of cores.

Bending Radius: Fixed installation: 8 x cable height.

*Variants with composite constructions are also available on request.


Cable Design Parameters

Part Number Nominal Cross Sectional Area
(Sq. mm)
Overall Dimensions
(mm)
Approx. Weight
(kg/km)
120810401105 4 x 1.5 15.0 x 5.0 150
120810411105 4 G 1.5 15.0 x 5.0 150
120810411205 4 G 2.5 18.5 x 5.7 210
120810410004 4 G 4 21.0 x 6.5 300
120810410006 4 G 6 23.0 x 7.0 385
120810410010 4 G 10 28.8 x 9.0 620
120810410016 4 G 16 36.8 x 10.8 990
120810410025 4 G 25 45.5 x 13.5 1550
120810410035 4 G 35 50.5 x 14.8 2030
120810410050 4 G 50 56.0 x 16.5 2650
120810410070 4 G 70 63.0 x 18.0 3650
120810410095 4 G 95 72.5 x 20.5 4550
120810511105 5 G 1.5 18.0 x 5.0 180
120810511205 5 G 2.5 22.0 x 5.7 260
120810510004 5 G 4 27.0 x 6.5 380
120810510006 5 G 6 27.0 x 7.0 480
120810510010 5 G 10 34.5 x 9 780
120810711105 7 G 1.5 26.0 x 5.0 260
120810711205 7 G 2.5 32.3 x 5.7 380
120810710004 7 G 4 40.0 x 6.8 550
120810801105 8 x 1.5 29.0 x 5.0 300
120810811105 8 G 1.5 29.0 x 5.0 300
120810811205 8 G 2.5 34.5 x 5.7 405
120811011105 10 G 1.5 35.0 x 5.0 360
120811210001 12 G 1*** 33.5 x 4.5 320
120811201105 12 x 1.5 40.5 x 5 420
120811211105 12 G 1.5 40.5 x 5 420
120811211205 12 G 2.5 50.5 x 5.7 620
120811210004 12 G 4 57 x 6.8 880
120811411105 14 G 1.5 47.5 x 5 490
120811611105 16 G 1.5 53.5 x 5 560
120811810001 18 G 1*** 50.5 x 4.5 470
120811811105 18 G 1.5 58.0 x 5.0 620
120812410001 24 G 1*** 6.5 x 4.5 610

Note:

  • ***H05VVH6-F Cables

Electrical Parameters

Part Number Nominal Cross Sectional Area
(Sq. mm)
Permissible Current
Rating (A)**
Voltage Drop (∆U) at
cos Φ = 0.8 (V/A x km)
120810401105 4 x 1.5 20 20.2
120810411105 4 G 1.5 20 20.2
120810411205 4 G 2.5 27 12.3
120810410004 4 G 4 36 7.8
120810410006 4 G 6 48 5.3
120810410010 4 G 10 63 3.2
120810410016 4 G 16 85 2
120810410025 4 G 25 112 1.3
120810410035 4 G 35 138 0.97
120810410050 4 G 50 168 0.74
120810410070 4 G 70 213 0.55
120810410095 4 G 95 258 0.42
120810511105 5 G 1.5 18 20.2
120810511205 5 G 2.5 25 12.3
120810510004 5 G 4 36 7.8
120810510006 5 G 6 48 5.3
120810510010 5 G 10 63 3.2
120810711105 7 G 1.5 15 20.2
120810711205 7 G 2.5 20 12.3
120810710004 7 G 4 25 7.8
120810801105 8 x 1.5 14 20.2
120810811105 8 G 1.5 14 20.2
120810811205 8 G 2.5 20 12.3
120811011105 10 G 1.5 12 20.2
120811210001 12 G 1*** 8 38.2
120811201105 12 x 1.5 11 20.2
120811211105 12 G 1.5 11 20.2
120811211205 12 G 2.5 16 12.3
120811210004 12 G 4 20 7.8
120811411105 14 G 1.5 11 20.2
120811611105 16 G 1.5 10 20.2
120811810001 18 G 1*** 6 38.2
120811811105 18 G 1.5 8 20.2
120812410001 24 G 1*** 6 38.2

Note:

  • ***H05VVH6-F Cables
  • **Ambient temperature: 30°C
Get a Quote