Application
These are standard wall auto cables ideal for use in motor wirings of fans and sensor applications in automobiles.
Standards
Based on ISO 6722-1
Temperature Range (3000 Hrs)
-40°C to +105°C
Cable Construction
Soft annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare conductor construction according to ISO 6722-1
Soft PVC insulation with properties according to ISO 6722-1, Class B
Special Properties
Conductor with cross-section > 6 mm² are also suitable as battery cable
Packing
Available in 100 mtrs. Longer length available in spools or wooden drums.
Cabel Design Parameters
Nom. Cross-Section (mm²) |
No. of Strands |
Max. Strand Diameter (mm) |
Max. Conductor Diameter (mm) |
Max. DC Conductor Resistance at 20°C (Ω/km) |
Nominal Insulation Thickness (mm) |
Overall Diameter (mm) | |
Min. | Tolerance | ||||||
0.5 | 16 | 0.21 | 0.21 | 37.1 | 0.6 | 2.0 | 2.3 |
0.75 | 24 | 0.21 | 0.21 | 24.7 | 0.6 | 2.0 | 2.5 |
1 | 32 | 0.21 | 0.21 | 18.5 | 0.6 | 2.4 | 2.7 |
1.5 | 30 | 0.26 | 0.26 | 12.7 | 0.6 | 2.7 | 3.0 |
2 | 40 | 0.26 | 0.26 | 9.42 | 0.6 | 2.9 | 3.3 |
2.5 | 50 | 0.26 | 0.26 | 7.6 | 0.7 | 3.3 | 3.6 |
3 | 60 | 0.26 | 0.26 | 6.15 | 0.7 | 3.5 | 4.1 |
4 | 56 | 0.31 | 0.31 | 4.71 | 0.8 | 4.0 | 4.4 |
6 | 84 | 0.31 | 0.31 | 3.14 | 0.8 | 4.6 | 5.0 |
10 | 80 | 0.41 | 0.41 | 1.82 | 1.0 | 6.0 | 6.5 |
16 | 126 | 0.41 | 0.41 | 1.16 | 1.0 | 7.0 | 8.3 |
25 | 196 | 0.41 | 0.41 | 0.743 | 1.3 | 8.7 | 10.4 |
35 | 276 | 0.41 | 0.41 | 0.527 | 1.3 | 10.0 | 11.6 |
50 | 400 | 0.41 | 0.41 | 0.368 | 1.5 | 11.9 | 13.5 |
70 | 560 | 0.41 | 0.41 | 0.259 | 1.5 | 14.0 | 15.5 |
95 | 740 | 0.41 | 0.41 | 0.196 | 1.6 | 15.4 | 18.0 |
120 | 960 | 0.41 | 0.41 | 0.153 | 1.6 | 18.7 | 19.7 |