H05Z1Z1-F (318B)

H05Z1Z1-F (318B)

  • REACH
  • RoHS
  • CE
  • CPR Compliant
H05Z1Z1-F-(318B)
H05Z1Z1-F (318B) Cross

Application

Used as an indoor general wiring cable primarily for installations in public areas or in any application where fire safety is utmost important. The cable can be used as pendant lighting drops or as a general supply lead within hospital, hotels, airport, educational institutions, etc.

Standard

BS EN 50525-3-11

Technical Data

Nominal Voltage: U / U 300/500 V

Temperature Range: Flexing -5°C to +70°C. Fixed Installation : -30°C to +70°C

Minimum Bending Radius: Flexing 7.5 x cable ø; Fixed installation 4 x cable ø

Cable Construction

Conductor: Bare copper, fine wire conductors, as per EN 60228 Cl.5

Insulation: LSZH (Low Smoke Zero Halogen) core insulation Type TI6, BS EN 50363-7

Core colours: Harmonised core colour to HD 308 (Refer Appendix Table No. 1-1). Cores stranded in layers with optimal lay-length

Outer sheath: LSZH (Low Smoke Zero Halogen) outer sheath Type TM7, to BS EN 50363-8

Properties

Self-extinguishing and flame retardant according to IEC 60332-1-2

Please complete the part numbers for these cables by adding the suffix (in place of ‘z’) for the sheath colour required: 1 – black (RAL 9005), 3 – grey (RAL 7001), 5 – white (RAL 9010).

Cabel Design Parameters

Part Number No. of Cores & Nominal
Cross Sectional Area (Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Cable
Weight (kg/km)
03200101007z 2 x 0.5 5.3 72
03200102007z 3G 0.5 5.6 82
03200103007z 4G 0.5 6.1 82
03200104007z 5G 0.5 6.4 97
03200105007z 2 x 0.75 6.5 97
03200106007z 3 G 0.75 6.8 111
03200107007z 4 G 0.75 7.4 129
03200108007z 5 G 0.75 8.3 106
03200109007z 7 G 0.75 9.0 130
03200110007z 12 G 0.75 12.4 239
03200111007z 2 x 1 6.8 67
03200112007z 3 G 1 7.2 80
03200113007z 4 G 1 8.0 102
03200114007z 5 G 1 8.8 122
03200115007z 2 x 1.5 7.7 88
03200116007z 3 G 1.5 8.4 110
03200117007z 4 G 1.5 9.3 140
03200118007z 5 G 1.5 10.4 174
03200119007z 2 x 2.5 9.3 134
03200120007z 3 G 2.5 10.1 168
03200121007z 4 G 2.5 11.0 208
03200122007z 5 G 2.5 12.3 257
03200123007z 2 x 4 10.3 183
03200124007z 3 G 4 11.4 231
03200125007z 4 G 4 12.5 287
03200126007z 5 G 4 14.1 362

Note:

  • *G = With green/yellow earth core
  • x = Without green/yellow earth core
  • For electrical parameters refer table 11.1, ,11.2, 11.3 of Appendix

*Construction Product Regulation (CPR) is a regulation issued by the European Union with the purpose of regulating the limits of fire resistance and dangerous substances in the materials used in construction. This regulation applies to all products intended to be incorporated, permanently, in construction. Above link provides the DOP (declaration of performance) for the CPR compliance for the product.)

Get a Quote

Request A Quote

Please Wait...