JZ-YCY BK 0.6/1.0 KV

JZ-YCY BK 0.6/1.0 KV

  • REACH
  • RoHS
  • CE
JZ-YCY BK 0.6/1.0 KV
JZ-YCY BK 0.6/1.0 KV Cross

Application

Wiring cable in tool machinery, conveyor belts and production lines, plant engineering, Industrial machinery, air conditioning, steel production plants and rolling mills. The dense coverage of copper screening offers EMI compliance.

Standard

Adapted to DIN VDE 0262/12.95 and 0281 Part 13 with insulation thickness for 1 kV type.

Technical Data

Nominal Voltage: UO / U 0.6 / 1kV

Insulation Resistance: Min. 20 GΩ x cm

Temperature Range: Flexing -5°C to +70°C. Fixed installation -30°C to +70°C

Minimum Bending Radius: Flexing 20 x cable ø. Fixed installation 6 x cable ø

Test Voltage: 4000V

Breakdown Voltage: Min. 8000V

Cable Construction

Bare copper, fine wire conductors, to EN 60228 Cl.5

Core insulation of special PVC TI2, EN 50363-3.

Black Core with continuous white numbering to DIN VDE 0293.

Green/yellow earth core in outer layer (3 cores and above).

Cores stranded in layers with optimal lay-length.

PVC inner jacket, Black color.

Tinned copper, braided screen, approx 85% coverage

Special PVC outer sheath TM2, to EN 50363-4.1.

Colour Black (RAL 9005).

Properties

PVC self-extinguishing and flame retardant according to IEC 60332-1-2.

UV & weather resistant according to ASTM G 154.

Ozone resistant according to EN 50396.

Cabel Design Parameters

Part Number No. of Cores & Nominal
Cross Sectional Area (Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Cable
Weight (kg/km)
031400201075 2 x 0.75 10.5 34.4 150
031400311075 3G 0.75 10.9 40.9 165
031400301075 3 x 0.75 10.9 40.9 165
031400411075 4G 0.75 11.4 49.8 185
031400401075 4 x 0.75 11.4 49.8 185
031400511075 5G 0.75 12.1 60.0 212
031400501075 5 x 0.75 12.1 60.0 212
031400711075 7G 0.75 12.9 74.9 247
031400701075 7 x 0.75 12.9 74.9 247
031401211075 12G 0.75 15.8 138.7 389
031401201075 12 x 0.75 15.8 138.7 389
031401811075 18G 0.75 18.0 185.5 510
031402511075 25G 0.75 20.7 243.4 676
031400200001 2 x 1 10.8 38.9 161
031400310001 3G 1 11.2 50.4 181
031400300001 3 x 1 11.2 50.4 181
031400410001 4G 1 11.8 59.4 203
031400400001 4 x 1 11.8 59.4 203
031400510001 5G 1 12.6 70.8 235
031400710001 7G 1 13.3 107.3 281
031401210001 12G 1 16.4 165.7 433
031401810001 18G 1 18.7 233.9 581
031402510001 25G 1 21.6 304.6 771
031400201105 2 x 1.5 11.8 50.3 196
031400311105 3G 1.5 12.3 62.4 219
031400301105 3 x 1.5 12.3 62.4 219
031400411105 4G 1.5 13.0 77.9 252
031400401105 4 x 1.5 13.0 77.9 252
031400511105 5G 1.5 13.9 93.4 293
031400711105 7G 1.5 15 143.3 366
031401211105 12G 1.5 18.7 222.3 572
031401811105 18G 1.5 21.8 309 785
031402511105 25G 1.5 25.1 411.1 1045
031400311205 3G 2.5 13.5 91.9 279
031400411205 4G 2.5 14.6 137.7 349
031400511205 5G 2.5 15.7 158.8 403
031400711205 7G 2.5 17.0 209 493
031401211205 12G 2.5 21.7 333.7 802
031400410004 4G 4 17.0 195 483
031400510004 5G 4 18.6 235 581
031400710004 7G 4 20.1 308 704
031400410006 4G 6 18.2 269 590
031400510006 5G 6 19.7 327 706
031400710006 7G 6 21.8 437 895
031400410010 4G 10 21.7 425.5 880
031400510010 5G 10 23.0 521.9 1027
031400410016 4G 16 24.3 666.5 1219
031400510016 5G 16 26.7 820.1 1487
031400410025 4G 25 29.8 1007 1844
031400510025 5G 25 31.6 1242.1 2167
031400410035 4G 35 32.7 1384.4 2368
031400410050 4G 50 39.6 2032.2 3471
031400410070 4G 70 44.5 2824.2 4602
031400410095 4G 95 51.0 3706.2 6050
031400410120 4G 120 58.1 4650.3 7727

Note:

  • *G = With green/yellow earth core
  • x = Without green/yellow earth core
  • For current ratings refer table no. 12-1 & voltage drop refer table no. 12-2 of Appendix
  • For current ratings to DIN VDE 0298-4 refer table no. 12-3 of Appendix.