PVC/PVC 3 CORE SUBMERSIBLE FLAT CABLE

PVC/PVC 3 core Submersible Flat Cable

  • REACH
  • RoHS
  • CE
PVC/PVC 3 core Submersible Flat Cable
PVC/PVC 3 core Submersible Flat Cable Cross

Application

The PVC insulated and sheathed 3 core flat cables are mainly used in pump connections. They are also used in many industrial applications. The sheath is specially made out to resist tough and difficult outdoor conditions & excellent resistant to water.

Technical Data

Approvals: IS 694 marked, FIA/TAC

Conductor: Electrolytic grade annealed copper

Core Colour: Red, yellow (centre core), blue

Conductor: Strands of electrolytic annealed plain copper are multi-drawn for uniformity of resistance, dimension and flexibility.

Sheath Colour: Black

Voltage Grade: Upto and including 1100V

Packing: Standard packing of 100 mtr. in coils. Longer length available on request.

Variants Available

Part Number Specifications
PVC 70°C IS 694, IS 8130 Class 2 (1.5 & 2.5 Sq. mm), for others class 5, IS 5831 Type A insulation & ST-1 sheath.
HR 85°C IS 694, IS 8130 Class 2 (1.5 & 2.5 Sq. mm), for others class 5, IS 5831 Type C insulation & ST-2 sheath.

Cabel Design Parameters

Kindly complete the part numbers for these cables by adding the suffix (in place of ‘y’) for the cable type
1 – PVC 70°C, 3 – PVC HR 85°C.

Part Number Conductor construction Conductor
resistance at 20 °C
(Ω/km) Max.
Nom. Insulation
thickness (mm)
Nominal Sheath
Thickness
(mm)
Approx. overall dimensions
(W X H) (mm) +/- 0.5 mm
Current carrying
capacity (Ampere)
Cross sectional
area (Sq. mm)
No./Max. dia of capacity (Ampere)
strands (mm)
0118110102y1 0.5 16/0.2 39.0 0.6 0.9 9.60 X 4.90 4
0118110202y1 0.75 24/0.2 26.0 0.6 0.9 10.5 X 5.20 7
0118110302y1 1 32/0.2 19.5 0.6 0.9 11.0 X 5.40 12
0118110402y1 1.5* 22/0.3 12.1 0.6 0.9 12.0 X 5.6 18
0118110502y1 2.5* 36/0.3 7.41 0.7 1.0 13.0 X 6.2 24
0118110602y1 4 56/0.3 4.95 0.8 1.0 15.3 X 7.1 28
0118110702y1 6 84/0.3 3.30 0.8 1.1 19.2 X 8.4 36
0118110802y1 10 140/0.3 1.91 1.0 1.4 24.2 X 10.4 48
0118110902y1 16 126/0.4 1.21 1.0 1.4 29.0 X 12.4 64
0118111002y1 25 196/0.4 0.78 1.2 2.0 36.5 X 15.7 80
0118111102y1 35 276/0.4 0.554 1.2 2.0 40.5 X 17.2 100
0118111202y1 50 396/0.4 0.386 1.4 2.2 46.5 X 19.3 130
0118111302y1 70 360/0.5 0.272 1.4 2.2 52.0 X 21.0 192
0118111402y1 95 480/0.5 0.206 1.6 2.4 61.0 X 24.5 230
  • For current ratings refer table no. 9-1, for voltage drop refer table no. 9-2.

Current rating conversion factor for deviating ambient temperature

Multiply the current carrying capacity of the cable by the factors given below for various ambient temperature.

Ambient Temperature (°C) Derating Factor
25 1.25
30 1.16
35 1.09
40 1.00
45 0.90
50 0.81
55 0.74
60 0.68