PVC/PVC 3 core Submersible Flat Cable
- REACH
- RoHS
- CE
Application
The PVC insulated and sheathed 3 core flat cables are mainly used in pump connections. They are also used in many industrial applications. The sheath is specially made out to resist tough and difficult outdoor conditions & excellent resistant to water.
Technical Data
Approvals: IS 694 marked, FIA/TAC
Conductor: Electrolytic grade annealed copper
Core Colour: Red, yellow (centre core), blue
Conductor: Strands of electrolytic annealed plain copper are multi-drawn for uniformity of resistance, dimension and flexibility.
Sheath Colour: Black
Voltage Grade: Upto and including 1100V
Packing: Standard packing of 100 mtr. in coils. Longer length available on request.
Variants Available
Part Number | Specifications |
PVC 70°C | IS 694, IS 8130 Class 2 (1.5 & 2.5 Sq. mm), for others class 5, IS 5831 Type A insulation & ST-1 sheath. |
HR 85°C | IS 694, IS 8130 Class 2 (1.5 & 2.5 Sq. mm), for others class 5, IS 5831 Type C insulation & ST-2 sheath. |
Cabel Design Parameters
Kindly complete the part numbers for these cables by adding the suffix (in place of ‘y’) for the cable type
1 – PVC 70°C, 3 – PVC HR 85°C.
Part Number | Conductor construction | Conductor resistance at 20 °C (Ω/km) Max. |
Nom. Insulation thickness (mm) |
Nominal Sheath Thickness (mm) |
Approx. overall dimensions (W X H) (mm) +/- 0.5 mm |
Current carrying capacity (Ampere) |
|
Cross sectional area (Sq. mm) |
No./Max. dia of capacity (Ampere) strands (mm) |
||||||
0118110102y1 | 0.5 | 16/0.2 | 39.0 | 0.6 | 0.9 | 9.60 X 4.90 | 4 |
0118110202y1 | 0.75 | 24/0.2 | 26.0 | 0.6 | 0.9 | 10.5 X 5.20 | 7 |
0118110302y1 | 1 | 32/0.2 | 19.5 | 0.6 | 0.9 | 11.0 X 5.40 | 12 |
0118110402y1 | 1.5* | 22/0.3 | 12.1 | 0.6 | 0.9 | 12.0 X 5.6 | 18 |
0118110502y1 | 2.5* | 36/0.3 | 7.41 | 0.7 | 1.0 | 13.0 X 6.2 | 24 |
0118110602y1 | 4 | 56/0.3 | 4.95 | 0.8 | 1.0 | 15.3 X 7.1 | 28 |
0118110702y1 | 6 | 84/0.3 | 3.30 | 0.8 | 1.1 | 19.2 X 8.4 | 36 |
0118110802y1 | 10 | 140/0.3 | 1.91 | 1.0 | 1.4 | 24.2 X 10.4 | 48 |
0118110902y1 | 16 | 126/0.4 | 1.21 | 1.0 | 1.4 | 29.0 X 12.4 | 64 |
0118111002y1 | 25 | 196/0.4 | 0.78 | 1.2 | 2.0 | 36.5 X 15.7 | 80 |
0118111102y1 | 35 | 276/0.4 | 0.554 | 1.2 | 2.0 | 40.5 X 17.2 | 100 |
0118111202y1 | 50 | 396/0.4 | 0.386 | 1.4 | 2.2 | 46.5 X 19.3 | 130 |
0118111302y1 | 70 | 360/0.5 | 0.272 | 1.4 | 2.2 | 52.0 X 21.0 | 192 |
0118111402y1 | 95 | 480/0.5 | 0.206 | 1.6 | 2.4 | 61.0 X 24.5 | 230 |
- For current ratings refer table no. 9-1, for voltage drop refer table no. 9-2.
Current rating conversion factor for deviating ambient temperature
Multiply the current carrying capacity of the cable by the factors given below for various ambient temperature.
Ambient Temperature (°C) | Derating Factor |
25 | 1.25 |
30 | 1.16 |
35 | 1.09 |
40 | 1.00 |
45 | 0.90 |
50 | 0.81 |
55 | 0.74 |
60 | 0.68 |