Ratna CO-X-Wire
Ratna CO-X-Cross

Application

High quality co-axial for cable TV network for notch free attenuation values over wide range of frequencies. The special jacketing offers increased life even in rugged conditions.

Technical Data

Conductor: The central conductor is made of solid electrolytic grade annealed plain copper conductor, which has distinct advantages over traditional copper conductor

Insulation: The insulation provided over the conductor is of foam PE

Screen: Aluminium mylar tape is provided over the insulated conductor to shield the conductor and ensures disturbance free transmission of signals

Braiding: The braiding is generally provided with 60% coverage of ATC (Annealed Tinned Copper) / Al alloy

Jacket: Specially formulated PVC, for rugged outdoor usage.

Marking: The cables are marked ‘RATNA CO-X’

Cabel Design Parameters

Construction Details Cable Type
RG 59 F RG 6 F* RG 11 F
Part Number 010501010791 0 01050102079 010501030791
Inner conductor Copper Copper Copper
Nominal Diameter (mm) 0.8 1.02 1.63
Dielectric Foam PE Foam PE Foam PE
Nominal Diameter (mm) 3.5 4.5 7.0
Outer Conductor First Bonded Al Tape Bonded Al Tape Bonded Al Tape
Outer Conductor Second Tinned Cu/Al Braid Tinned Cu/Al Braid Tinned Cu/Al Braid
Nominal Coverage (%) 60 60 60
PVC Jacket Black Black Black
Nominal Cable Diameter (mm) 6.2 7.0 10
  • RG 6 F is also available with CCS conductor and the applicable Part number shall be 010501040791.
Construction Details Cable Type – Armoured
RG 59 F RG 6 F* RG 11 F
Part Number 010501050791 010501060791 010501070791
Nominal Cable Diameter (mm) 10.5 11.4 14.6
  • RG 6 F armoured is also available with CCS conductor and the applicable Part number shall be 010501080791.

Electrical Parameters

Parameters Cable Type
RG 59 F RG 6 F RG 11 F
Inner Conductor-Max Resistance at 20°C (Ω/100m) 3.43 2.1 0.8
Nominal Capacitance (pF/m) 53 53 53
Characteristic Impedance (Ω) 75 75 75
Velocity of Propagation (%) 85 85 85
Dielectric Strength (KV) > 1 > 1 > 1
Minimum Bending Radius (mm) 60 65 75
Maximum Attenuation at 20°C (dB/100m) at Max. Max. Max.
5 MHz 2.8 1.9 1.2
50 MHz 6.7 5.3 3.1
100 MHz 8.8 7.0 4.2
200 MHz 12.4 9.9 6.0
250 MHz 13.4 10.5 6.7
300 MHz 14.6 11.5 7.3
350 MHz 15.7 12.4 7.9
400 MHz 16.7 13.3 8.5
450 MHz 17.7 14.3 9.0
500 MHz 18.7 14.9 9.5
550 MHz 19.5 15.7 9.9
600 MHz 20.3 16.4 10.4
750 MHz 22.8 18.3 11.9
800 MHz 24.5 19.5 12.4
900 MHz 24.7 20.1 13.0
1000 MHz 26.6 21.4 14.2