These are silicone multicore cables with galvanized steel braiding for robust application. These cables are used in the areas having large band of extreme temperatures and can be used in the areas with increased mechanical stress. They are especially used in steel production industries, cement industries, glass industries, aviation industries, ship buildings, etc.

Standards

Adapted to DIN VDE 0250 part 1 and part 816.

Technical Data

Voltage Rating: UO / U – 300 / 500V

Test Voltage: 2000V

Temperature Range: -50°C to +180°C (up to + 220°C for short time)

Temperature Limit at the Conductor: In operation +180°C

Insulation Resistance: Min. 200 MΩ x km

Minimum Bending Radius: Flexing 10 x cable ø. Fixed Installation 5 x cable ø

Cable Construction

Tinned copper conductor to Cl. 5, EN 60228.

Silicone core insulation.

Core identification to DIN VDE 0293 – 308 colour coded or black cores with continuous white numbers.

For 2 – cores brown, blue.

For 3 – cores and above cable provided without protective conductor.

For 6 – cores and above all black cores with number coding.

Cores stranded in layers with optimal lay – length.

Outer jacket of Silicone.

Jacket colour – red brown

Glass fibre tape over the jacket.

Galvanised steel wire outer braiding.

Properties

Galvanised steel braid over the sheath protects against the external mechanical damages.íhe cable has better durability in harsh environments and applications compared to the conventional silicone cables.ö

Advantages: Hardly changes of dielectric strength and the insulation resistance also at high temperatures, high ignition or flash point, in case of fire, forms an insulating layer of SiO2.

Resistant to: High molecular oils, fats from vegetables and animals, alcohols, plasticisers and clopenes, diluted acids, dyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV.

Halogen – Free: According to IEC 60754 – 2.

Behaviour in Fire: Flame propagation test according to EN 60332 – 1 – 2

Cabel Design Parameters

Part Number No. of Cores & Nominal
Cross Sectional Area (Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Cable
Weight (kg/km)
080400201075 2 x 0.75 7.6 13 94
080400311075 3 x 0.75 8.0 19.6 102
080400411075 4 x 0.75 8.6 26.1 121
080400511075 5 x 0.75 9.3 32.6 134
080400711075 7 x 0.75 10.3 45.6 159
080400200001 2 x 1 7.8 17.4 103
080400310001 3 x 1 8.2 26.1 112
080400410001 4 x 1 8.9 34.8 131
080400510001 5 x 1 9.6 43.5 148
080400710001 7 x 1 10.6 60.8 180
080400201105 2 x 1.5 8.7 25.5 124
080400311105 3 x 1.5 9.2 38.2 142
080400411105 4 x 1.5 9.9 50.9 162
080400511105 5 x 1.5 10.7 63.7 189
080400711105 7 x 1.5 11.9 89.1 229
080401211105 12 x 1.5 15.3 152.8 355
080400201205 2 x 2.5 10.0 42.4 167
080400311205 3 x 2.5 10.6 63.7 191
080400411205 4 x 2.5 11.5 84.9 224
080400511205 5 x 2.5 12.5 106.1 260
080400711205 7 x 2.5 13.9 148.5 321
080400200004 2 x 4 11.8 67.5 234
080400300004 3 x 4 12.5 101.2 269
080400400004 4 x 4 14.0 135 329
080400500004 5 x 4 15.1 168.7 385
080400200006 2 x 6 14.2 101.2 324
080400300006 3 x 6 15.0 151.8 376
Get a Quote