THIN WALLED SINGLE & MULTICORE – ANNEALED TINNED COPPER

THIN WALLED SINGLE & MULTICORE – ANNEALED TINNED COPPER

  • REACH
  • RoHS
  • CE
Tinned copper cables
Tinned copper cables Cross

Application

Tin plated single and multi core cable for starting, charging and instrument panel circuits in automobiles.

Standards

In accordance to ISO 6722-1

Cable Construction

Electrolytic annealed tinned copper as per ISO 6722-1

PVC with properties according to according to ISO 6722-1, Class B (105°C)

Packing

Available in 100 mtrs. Longer length available in spools or wooden drums.

Cabel Design Parameters

Nominal
Cross-Section
(mm²)
No. of
Strands
Max. Strand
Diameter mm
Outer Diameter
(max.) (mm)
Max. DC Conductor
Resistance
at 20°C (Ω/km)
1.0 32 0.20 2.1 19.1
1.5 21 0.30 2.4 13.0
2.5 35 0.30 3.0 7.82
4.0 56 0.30 3.7 4.85
6.0 84 0.30 4.3 3.23
10.0 80 0.40 6.0 1.85

Tinned Copper 2 Core Cables (Flat Twins)

Standards

In accordance to ISO 6722-1

Cable Construction

PVC with properties according to according to ISO 6722-1, Class B (105°C)

PVC Sheathed 105°C

Packing

Available in 100 mtrs. Longer length available in spools or wooden drums.

Tinned Copper 2 Core Cables (Flat Twins)
Tinned Copper 2 Core Cables (Flat Twins)

No. of Cores X
Nominal Cross-Section
(mm²)
No. of
Strands
Max. Strand
Conductor (mm)
Max. Overall
Diameter (mm)
Sheath Colour
Core Colour
2 x 1.5 21 0.30 3.5 x 5.8 White/ Black Red, Black
2 x 2.5 35 0.30 3.9 x 6.7

Tinned Copper 2 Core Cables (Round Twins)

Standards

In accordance to ISO 6722-1

Cable Construction

PVC with properties according to according to ISO 6722-1, Class B (105°C)

PVC Sheathed 105°C

Packing

Available in 100 mtrs. Longer length available in spools or wooden drums

Tinned Copper 2 Core Cables (Round Twins)
Tinned Copper 2 Core Cables (Round Twins)

No. of Cores X
Nominal Cross-Section
(mm²)
No. of
Strands
Max. Strand
Conductor (mm)
Max. Overall
Diameter (mm)
Sheath Colour
Core Colour
2 x 1.5 21 0.30 6.4 Black Black, Red
2 x 2.5 35 0.30 6.7

Tinned Copper 3 Core Cables

Standards

In accordance to ISO 6722-1

Cable Construction

PVC with properties according to according to ISO 6722-1, Class B (105°C)

PVC Sheathed 105°C

Packing

Available in 100 mtrs. Longer length available in spools or wooden drums

Tinned Copper 3 Core Cables
Tinned Copper 3 Core Cables

No. of Cores X
Nominal Cross-Section
(mm²)
No. of
Strands
Max. Strand
Conductor (mm)
Max. Overall
Diameter (mm)
Sheath Colour
Core Colour
2 x 1.5 21 0.30 5.9 White / Black Black, Red, Green
2 x 2.5 35 0.30 7.4
Get a Quote

Request A Quote

Please Wait...