UL 1275

  • REACH
  • RoHS
  • CE
UL 1275Wire
UL 1275 Cross

Application

PVC-insulated heavy wall lead wire, for use as hook – up wire and for internal wiring on refrigeration equipments.

Technical Data

Standard: UL – Std. 758 , CSA C 22.2 No.210

Temperature Range: -20°C to 105°C

Nominal Voltage: 600V

Test Voltage (Spark Test):

AWG 18 to 16 : 6kV

≥ AWG 8: 7.5kV

Bending Radius: Fixed installation 5 x cable ø

Cable Construction

Annealed plain or tinned stranded copper conductor.
PVC – core insulation Type TW, Recognized Component QMTT2 heat and damp resistant.

Properties

  • Conditionally resistant to oils.
  • PVC self – extinguishing and flame retardant, test method to UL VW-1 and CSA FT 1 / FT 2

Cable Design Parameters

Kindly complete the part numbers for these cables by adding the suffix (in place of ‘xx’) for the insulation colour required: 01 – green, 02 – black, 03 – red, 04 – blue, 05 – yellow, 06 – green/yellow, 07 – white, 08 -Violet, 09 – brown, 10 – orange, 11 – pink, 12 – grey, 13 – light blue.

Part Number AWG No. No. of Cores and
Nominal Cross Sectional
(Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Cable
Weight (kg/km)
06050101xx30 18 1 x 0.82 4.3 8.3 27.4
06050102xx30 16 1 x 1.32 4.6 13.5 35.1
06050103xx30 14 1 x 2.08 5.0 20.4 44.9
06050104xx30 12 1 x 3.31 5.5 32.5 60.6
06050105xx30 10 1 x 5.26 6.1 51.7 84.5
Get a Quote