UL 1569

  • REACH
  • RoHS
  • CE
UL 1569 Wire
UL 1569 Cross

Application

These cables are used for internal wiring of switchboards, electronic and electrical equipment, e. g. households, radio of televisions, monitor and control desks.

Technical Data

Standard: UL – Std. 758 , CSA C 22.2 No.210

Nominal Voltage: 300V

Test Voltage: 2000V Test Voltage (Spark Test)

AWG 26-20: 4kV, AWG 10 -18: 5kV

Temperature Range: Flexible -5°C to + 105°C. Fixed installation -20°C to + 105°C CSA – AWM I A/B

Bending Radius: Flexing 10 x cable ø. Fixed installation 5 x cable ø

Cable Construction

Annealed plain or tinned stranded copper conductor.
PVC – core insulation according to UL – Standard 1581, Class 43 Tab. 50.182, heat and damp resistant.

Properties

  • Conditionally resistant to oils, solvents, acids and dyes.
  • PVC self – extinguishing and flame retardant, test method to UL VW-1 and CSA FT 1 / FT 2

Cable Design Parameters

Kindly complete the part numbers for these cables by adding the suffix (in place of ‘xx’) for the insulation colour required: 01 – green, 02 – black, 03 – red, 04 – blue, 05 – yellow, 06 – green/yellow, 07 – white, 08 -Violet, 09 – brown, 10 – orange, 11 – pink, 12 – grey, 13 – light blue.

Part Number AWG No. No. of Cores and
Nominal Cross Sectional
(Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Cable
Weight (kg/km)
06040101xx30 26 1 x 0.14 1.3 1.4 3.0
06040102xx30 24 1 x 0.21 1.5 2.1 4.3
06040103xx30 22 1 x 0.33 1.6 3.5 5.8
06040104xx30 20 1 x 0.52 1.8 5.2 8.0
06040105xx30 18 1 x 0.82 2.1 8.3 12.0
06040106xx30 16 1 x 1.32 2.5 13.5 18.4
06040107xx30 14 1 x 2.08 3.0 20.4 27.3
06040108xx30 12 1 x 3.31 3.5 32.5 41.3
06040109xx30 10 1 x 5.26 4.1 51.7 62.8
Get a Quote

Request A Quote

Please Wait...