UL 3289/3321/3173/3271/3344 XLPE CABLE

UL 3289/3321/3173/3271/3344 XLPE CABLE

  • REACH
  • RoHS
  • CE
UL 3289/3321/3173/3271/3344 XLPE CABLE Wire
UL 3289/3321/3173/3271/3344 XLPE CABLE Cross

Application

These cables have excellent resistance to abrasion, deformation, cut-through and chemical attack. This wire is widely used in appliances, transformers, electrical heating, motors, ballast, lighting and cooking equipment. Suitable for use as Appliance Wiring Material (AWM), coil leads and as Class B IEEE 130°C Class Motor Leads. Economical replacement for silicone rubber/glass braid insulated wire and cable.

Technical Data

Standard: UL – Std. 758. Complies to CSA No. 22.2 210 and 127

Nominal Voltage: 600V

Test Voltage (Spark Test):

AWG 22 and 20: 5kV

AWG 18 to 10: 6kV

≥ AWG 8: 7.5kV

Temperature Range: Flexible -5°C to +150°C. Fixed installation -50°C to +150°C

Temperature at Conductor: Max. UL : +150°C

Bending Radius: Approx. 5 x cable ø

Cable Construction

  • Annealed plain or tinned stranded copper conductor.
  • XLPE insulation according to UL- Std. 1581 Table 50.232, Complies to CSA No. 22.2 210 and 127.

Properties

  • PVC self – extinguishing and flame retardant, test method to FT 2

Cable Design Parameters

AWG Metric
Cross Section
Area (Sq. mm)
No. of
Strands/Strand Dia.
(mm)
Max. DC Conductor
Resistance for
ABC @ 20°C (Ω/km)
Max. DC Conductor
Resistance for
ATC @ 20°C (Ω/km)
Insulation
Thickness
(mm)
Nominal Cable
Diameter (mm)
21 0.50 16/0.2 43.6 46.9 0.762 2.4
19 0.75 24/0.2 27.4 29.1 0.762 2.6
18 1.00 32/0.2 21.8 23.2 0.762 2.8
16 1.50 30/0.25 13.7 14.6 0.762 3.1
14 2.50 50/0.25 8.62 8.96 0.762 3.5
12 4.00 56/0.3 5.43 5.64 0.762 4.0
10 6.00 84/0.3 3.409 3.546 0.762 4.6
8 10.00 140/0.3 2.144 2.23 1.143 6.1
6 16.00 126/0.4 1.348 1.403 1.524 7.9
4 25.00 196/0.4 0.8481 0.882 1.524 9.1
2 35.00 276/0.4 0.5335 0.5548 1.524 10.7
1 50.00 296/0.4 0.423 0.4398 2.032 12.8
2/0 70.00 360/0.5 0.266 0.2766 2.032 14.8
3/0 95.00 480/0.5 0.211 0.2194 2.032 16.2
4/0 120.00 608/0.5 0.1673 0.1722 2.032 17.7

Kindly complete the part numbers for these cables by adding the suffix (in place of ‘xx’) for the insulation colour required: 01 – green, 02 – black, 03 – red, 04 – blue, 05 – yellow, 06 – green/yellow, 07 – white, 08 -violet, 09 – brown, 10 – orange, 11 – pink, 12 – grey, 13 – light blue Kindly complete the part numbers by adding the suffix (in place of ‘c’) for the conductor type required: 0 = annealed bare copper (ABC), 1 = annealed tinned copper (ATC)

AWG Metric
Cross Section
Area (Sq. mm)
Part Number
UL 3289 UL 3321 UL 3173 UL 3271 UL 3344
21 0.5 06090101xx9c 06090116xx9c 06090131xx9c 06090146xx9c 06090161xx9c
19 0.75 06090102xx9c 06090117xx9c 06090132xx9c 06090147xx9c 06090162xx9c
18 1.00 06090103xx9c 06090118xx9c 06090133xx9c 06090148xx9c 06090163xx9c
16 1.5 06090104xx9c 06090119xx9c 06090134xx9c 06090149xx9c 06090164xx9c
14 2.5 06090105xx9c 06090120xx9c 06090135xx9c 06090150xx9c 06090165xx9c
12 4.00 06090106xx9c 06090121xx9c 06090136xx9c 06090151xx9c 06090166xx9c
10 6.00 06090107xx9c 06090122xx9c 06090137xx9c 06090152xx9c 06090167xx9c
8 10.00 06090108xx9c 06090123xx9c 06090138xx9c 06090153xx9c 06090168xx9c
6 16.00 06090109xx9c 06090124xx9c 06090139xx9c 06090154xx9c 06090169xx9c
4 25.00 06090110xx9c 06090125xx9c 06090140xx9c 06090155xx9c 06090170xx9c
2 35.00 06090111xx9c 06090126xx9c 06090141xx9c 06090156xx9c 06090171xx9c
1 50.00 06090112xx9c 06090127xx9c 06090142xx9c 06090157xx9c 06090172xx9c
2/0 70.00 06090113xx9c 06090128xx9c 06090143xx9c 06090158xx9c 06090173xx9c
3/0 95.00 06090114xx9c 06090129xx9c 06090144xx9c 06090159xx9c 06090174xx9c
4/0 120.00 06090115xx9c 06090130xx9c 06090145xx9c 06090160xx9c 06090175xx9c
Get a Quote

Request A Quote

Please Wait...